Digital Multimeter
PC510
High Accuracy True RMS
Multi Function
Temp Measurement
Standard Accessory:
1.
PC510 x 1
2.
Holster (H-50) x 1pc.
3.
Test Leads (TL-82) x 1set
4.
Thermocouple (K-250PC) x 1pc
5.
Instruction Manual x 1pc
Optional Accessory:
1.
Clamp Probe (CL33DC)
2.
Clamp Probe (CL-22AD)
3.
Clamp Probe (CL-20D)
4.
Alligator Clip (CL-13) x 1set
5.
K-type adapter (K-AD)
6.
Carrying Case (C-CD)
7.
RS-232C cable (KB-RS2)
8.
Software (PC Link / PC Link Plus)
Features:
1.
AC True RMS
2.
Fast Response (5 times / sec. in digit and 60times / sec. in bargraph)
3.
Selectable 5 sensitivity for Frequency measurement
4.
Capacitance measurement 0.01nF up to 9999uF
5.
K-type temperature measurement –50oC ~ 1000oC
6.
Auto Lead Resistance Calibration
7.
0.08% Basic Accuracy at DCV function
8.
High resolution: 0.01 ohm, Voltage 0.01mV
9.
MAX, MIN recording mode
10.
MAX. MIN Capture mode (peak hold) 0.8ms in duration
11.
Zoom bargraph
12.
RS-232C Interface
13.
Data hold
14.
Relative Value
15.
Auto power off (Enable or Disable)
16.
Fast response Cont. Buzzer
17.
Tilt stand
18.
Set off Beeper function
General Specification:
Measuring Method
Display Counter
5000 counts
Bar graph 52 segments max.
Range Selection
Auto and Manual ranges
Over Display
"O.L"mark indication
Polarity
Automatic selection(only"-"is displayed)
Low Battery Indication
Sampling Rate
Numeral display
Approx.5times/sec
Bar graph
Approx.60times/sec
Accuracy Temperature
18~28
ºC 75% RH max. No condensation
Operating Temperature
0~50
°C 70% RH max. No condensation
Storage Temperature
(Battery removed)
-20~60
°C 80% RH max. No condensation
Environmental Condition
Operating altitude < 2000m, Pollution degree II
Power Supply
6LF22 x 1
Power Consumption
Approx. 5mA typical
Auto Power Off Timing
17min
Fuse Protection
0.63A/250V 5x20mm IR 1.5kA
12.5A/500V 6x32mm IR 20kA
Dimension and Weight
(including Holster)
179(H) x 87(W) x 54(D)mm, approx. 430g
Accessories
Instruction manual x 1
Holster(H-50)x 1
Test lead(TL-82) x 1set
Thormocouple (K-250PC) x 1
Safety
IEC 1010-1 CAT III Max.600V, CAT II Max. 1000V
E.M.C.
EN50081-1, EN50082-1
Measurement Range And Accuracy:
Range
Accuracy
Function-DCV
50.00mV
±(0.12%rdg+2dgt)
500.0mV
±(0.06%rdg+2dgt)
5.000V
±(0.08%rdg+2dgt)
50.00V
500.0V
1000V
Function-ACV
Bandwidth
50~60Hz
40~500Hz
up to 20kHz
50.00mV
±(0.5%rdg+5dgt)
±(0.8%rdg+3dgt)
0.5dB
500.0mV
5.000V
±(1%rdg+4dgt)
3dB
50.00V
500.0V
1000V
±(1.0%rdg+40dgt)
Unspec'd
Function-W
50.00W
±(0.4%rdg+6dgt)
500.0W
±(0.2%rdg+3dgt)
5.000kW
±(0.2%rdg+2dgt)
50.00kW
500.0kW
5.000MW
±(1.0%rdg+3dgt)
50.00MW
±(1.5%rdg+5dgt)
Open Voltage: <1.3VDC, <3VDC for 50W&500W range
Function-Capacity
50.00nF
±(0.8%rdg+3dgt)
500.0nF
5.000µF
±(1.0%rdg+3dgt)
50.00µF
±(2.0%rdg+3dgt)
500.0µF
±(3.5%rdg+5dgt)
9999µF
±(5.0%rdg+5dgt)
Function-DCA
500.0µA
±(0.2%rdg+4dgt)
5000µA
50.00mA
500.0mA
5.000A
10.00A
Function-ACA
Bandwidth
50~60Hz
40~1kHz
500.0µA
±(0.6%rdg+3dgt)
±(0.8%rdg+4dgt)
5000µA
50.00mA
500.0mA
±(1%rdg+3dgt)
±(1.0%rdg+4dgt)
5.000A
±(0.6%rdg+3dgt)
10.00A
Frequency
5.000Hz~125kHz
±(0.01%rdg+2dgt)
Temperture(PC520M/PC510)
-50ºC~1000ºC
±(0.3%rdg+3dgt)
Continity buzzer
Buzzer sounds at between 20W~120W
Open voltage: Approx. 3V
Diode test
Open voltage: Approx. 3.5V
Function:
50000 & 500000 count
5000 count
PC5000
PC520M
PC510
PC500
Best Accuracy in DCV
0.03%
0.08%
0.08%
0.08%
Built-in Memory 43,000points
PC Link system (RS232 interface)
True RMS
Capacitance
Frequency
Logic Frequency
Temperture K-type
Temperture Platinic thin film (Optional)
0.01 mV resolution
0.01 ohm resolution
Auto leads calibration for low ohm range
dBm measurement
Duty Cycle
%4-20mA
Diode test
Continity buzzer
MAX / MIN Recording
MAX / MIN Capture (Peak hold)
Zoom Bargraph
Data Hold
Relative measurement
Auto Range
Range hold
Auto Power Off (Enable or Disable)
Alarm for mis-pulg for Current range
Set off Beeper
Tilt stand
Page Top ^^
Copyright © 2002, Eurosax doo. All rights reserved.
Design by
websolutions.co.yu
.