Home
Authorised distrubutor for Sanwa and Hisatomi products.
Choose
Sanwa
Products
Hisatomi
Products
Eurosax
Products
About UsContact
  Home > Sanwa Products > Digital Multimeter > PC510
On Stock Products
Digital Multimeter
Analog Multitester
Clamp Meter
Earth Tester
Laser Power Meter
Lux Meter
Cord Tester
Optional Accessories


More info:
Sanwa website
 
Digital Multimeter
PC510
High Accuracy True RMS
Multi Function
Temp Measurement



 
Standard Accessory:

1. PC510 x 1
2. Holster (H-50) x 1pc.
3. Test Leads (TL-82) x 1set
4. Thermocouple (K-250PC) x 1pc
5. Instruction Manual x 1pc
 
 
Optional Accessory:

1. Clamp Probe (CL33DC)
2. Clamp Probe (CL-22AD)
3. Clamp Probe (CL-20D)
4. Alligator Clip (CL-13) x 1set
5. K-type adapter (K-AD)
6. Carrying Case (C-CD)
7. RS-232C cable (KB-RS2)
8. Software (PC Link / PC Link Plus)
 
 
Features:

1. AC True RMS
2. Fast Response (5 times / sec. in digit and 60times / sec. in bargraph)
3. Selectable 5 sensitivity for Frequency measurement
4. Capacitance measurement 0.01nF up to 9999uF
5. K-type temperature measurement –50oC ~ 1000oC
6. Auto Lead Resistance Calibration
7. 0.08% Basic Accuracy at DCV function
8. High resolution: 0.01 ohm, Voltage 0.01mV
9. MAX, MIN recording mode
10. MAX. MIN Capture mode (peak hold) 0.8ms in duration
11. Zoom bargraph
12. RS-232C Interface
13. Data hold
14. Relative Value
15. Auto power off (Enable or Disable)
16. Fast response Cont. Buzzer
17. Tilt stand
18. Set off Beeper function
 
 
General Specification:

Measuring Method
Display Counter 5000 counts
Bar graph 52 segments max.
Range Selection Auto and Manual ranges
Over Display "O.L"mark indication
Polarity Automatic selection(only"-"is displayed)
Low Battery Indication
Sampling Rate
Numeral display Approx.5times/sec
Bar graph Approx.60times/sec
Accuracy Temperature 18~28ºC 75% RH max. No condensation
Operating Temperature 0~50°C 70% RH max. No condensation
Storage Temperature
(Battery removed)
-20~60°C 80% RH max. No condensation
Environmental Condition Operating altitude < 2000m, Pollution degree II
Power Supply 6LF22 x 1
Power Consumption Approx. 5mA typical
Auto Power Off Timing 17min
Fuse Protection 0.63A/250V 5x20mm IR 1.5kA
12.5A/500V 6x32mm IR 20kA
Dimension and Weight
(including Holster)
179(H) x 87(W) x 54(D)mm, approx. 430g
Accessories Instruction manual x 1
Holster(H-50)x 1
Test lead(TL-82) x 1set
Thormocouple (K-250PC) x 1
Safety IEC 1010-1 CAT III Max.600V, CAT II Max. 1000V
E.M.C. EN50081-1, EN50082-1
 
 
Measurement Range And Accuracy:

Range
Accuracy
Function-DCV
50.00mV ±(0.12%rdg+2dgt)
500.0mV ±(0.06%rdg+2dgt)
5.000V ±(0.08%rdg+2dgt)
50.00V
500.0V
1000V
Function-ACV
Bandwidth
50~60Hz
40~500Hz
up to 20kHz
50.00mV ±(0.5%rdg+5dgt) ±(0.8%rdg+3dgt) 0.5dB
500.0mV
5.000V ±(1%rdg+4dgt) 3dB
50.00V
500.0V
1000V ±(1.0%rdg+40dgt) Unspec'd
Function-W
50.00W ±(0.4%rdg+6dgt)
500.0W ±(0.2%rdg+3dgt)
5.000kW ±(0.2%rdg+2dgt)
50.00kW
500.0kW
5.000MW ±(1.0%rdg+3dgt)
50.00MW ±(1.5%rdg+5dgt)
Open Voltage: <1.3VDC, <3VDC for 50W&500W range
Function-Capacity
50.00nF ±(0.8%rdg+3dgt)
500.0nF
5.000µF ±(1.0%rdg+3dgt)
50.00µF ±(2.0%rdg+3dgt)
500.0µF ±(3.5%rdg+5dgt)
9999µF ±(5.0%rdg+5dgt)
Function-DCA
500.0µA ±(0.2%rdg+4dgt)
5000µA
50.00mA
500.0mA
5.000A
10.00A
Function-ACA
Bandwidth
50~60Hz
40~1kHz

500.0µA ±(0.6%rdg+3dgt) ±(0.8%rdg+4dgt)
5000µA
50.00mA
500.0mA ±(1%rdg+3dgt) ±(1.0%rdg+4dgt)
5.000A ±(0.6%rdg+3dgt)
10.00A
Frequency
5.000Hz~125kHz ±(0.01%rdg+2dgt)
Temperture(PC520M/PC510)
-50ºC~1000ºC ±(0.3%rdg+3dgt)
Continity buzzer
Buzzer sounds at between 20W~120W
Open voltage: Approx. 3V
Diode test
Open voltage: Approx. 3.5V
 
 
Function:


50000 & 500000 count 5000 count
PC5000 PC520M PC510 PC500
Best Accuracy in DCV
0.03%
0.08% 0.08% 0.08%
Built-in Memory 43,000points



PC Link system (RS232 interface)
True RMS

Capacitance
Frequency
Logic Frequency



Temperture K-type


Temperture Platinic thin film (Optional)
0.01 mV resolution
0.01 ohm resolution
Auto leads calibration for low ohm range

dBm measurement


Duty Cycle


%4-20mA


Diode test
Continity buzzer
MAX / MIN Recording

MAX / MIN Capture (Peak hold)

Zoom Bargraph


Data Hold
Relative measurement

Auto Range
Range hold
Auto Power Off (Enable or Disable)
Alarm for mis-pulg for Current range



Set off Beeper
Tilt stand