Digital Multimeter
PC520M
Handheld Data
Logger DMM
Temp Measurement
43,000 logged data kept in built-in Memory

|
|
Standard Accessory:
1. |
PC520M x 1 |
2. |
Holster (H-50) x 1pc. |
3. |
Test Leads (TL-82) x 1set |
4. |
Alligator Clip (CL-13) x 1set |
5. |
Thermocouple (K-250PC) x 1pc |
6. |
Instruction Manual x 1pc |
|
|
|
Optional Accessory:
1. |
Clamp Probe (CL33DC) |
2. |
Clamp Probe (CL-22AD) |
3. |
Clamp Probe (CL-20D) |
4. |
K-type adapter (K-AD) |
5. |
Carrying Case (C-CD) |
6. |
RS-232C cable (KB-RS2) |
7. |
Software (PC Link / PC Link Plus) |
|
|
|
Features:
1. |
AC True RMS |
2. |
Fast Response (5 times / sec. in digit
and 60times / sec. in bargraph) |
3. |
Selectable 5 sensitivity for Frequency
measurement |
4. |
Capacitance measurement 0.01nF up
to 9999uF |
5. |
K-type temperature measurement –50oC
~ 1000oC |
6. |
Auto Lead Resistance Calibration |
7. |
0.08% Basic Accuracy at DCV function |
8. |
High resolution: 0.01 ohm, Voltage
0.01mV |
9. |
Data Logging Mode: |
10. |
43,000 data can be kept in built-in
memory. |
11. |
Call and Scrolling logged data |
12. |
Search MAX MIN data |
13. |
Search MAX & MIN data at turning
point |
14. |
Interval selection: |
|
ACV, DCV, ACA, DCA: 0.05s, 1s, 20s,
40s, 1min, 2min, 4min, 8min
oC & ohm: 0.2s, 1s, 20s, 40s, 1min, 2min,
4min, 8min
Hz: 0.4s, 1s, 20s, 40s, 1min, 2min, 4min, 8min |
15. |
Automatic Standby mode during data
logging to extend Battery life |
16. |
Automatic stopping data logging mode
when batteries are low to guarantee accuracy of
every logged data |
17. |
Download data logged to PC through
RS232 port. |
18. |
RS-232C Interface |
19. |
Data hold |
20. |
Auto power off (Enable or Disable) |
21. |
Fast response Cont. Buzzer |
22. |
Tilt stand |
23. |
Set off Beeper function |
|
|
|
General Specification:
Measuring Method |
|
Display Counter |
5000 counts
Bar graph 52 segments max. |
Range Selection |
Auto and Manual ranges |
Over Display |
"O.L"mark indication |
Polarity |
Automatic selection(only"-"is displayed) |
Low Battery Indication |
|
Sampling Rate |
Numeral display |
Approx.5times/sec |
Bar graph |
Approx.60times/sec |
|
Accuracy Temperature |
18~28ºC 75% RH max. No condensation |
Operating Temperature |
0~50°C 70% RH max. No condensation |
Storage Temperature
(Battery removed) |
-20~60°C 80% RH max. No condensation |
Environmental Condition |
Operating altitude < 2000m, Pollution degree
II |
Power Supply |
6LF22 x 1 |
Power Consumption |
Approx. 5mA typical |
Auto Power Off Timing |
17min |
Fuse Protection |
0.63A/250V 5x20mm IR 1.5kA
12.5A/500V 6x32mm IR 20kA |
Dimension and Weight
(including Holster) |
179(H) x 87(W) x 54(D)mm, approx. 430g |
Accessories |
Instruction manual x 1
Holster(H-50)x
1
Test lead(TL-82) x 1set
Thormocouple (K-250PC) x 1
Alligator Clip (CL-13) x 1set |
Safety |
IEC 1010-1 CAT III Max.600V, CAT II Max. 1000V |
E.M.C. |
EN50081-1, EN50082-1 |
|
|
|
Measurement Range And Accuracy:
Range |
Accuracy |
Function-DCV |
50.00mV |
±(0.12%rdg+2dgt) |
500.0mV |
±(0.06%rdg+2dgt) |
5.000V |
±(0.08%rdg+2dgt) |
50.00V |
500.0V |
1000V |
Function-ACV |
Bandwidth |
50~60Hz |
40~500Hz |
up
to 20kHz |
50.00mV |
±(0.5%rdg+5dgt) |
±(0.8%rdg+3dgt) |
0.5dB |
500.0mV |
5.000V |
±(1%rdg+4dgt) |
3dB |
50.00V |
500.0V |
1000V |
±(1.0%rdg+40dgt) |
Unspec'd |
Function-W |
50.00W |
±(0.4%rdg+6dgt) |
500.0W |
±(0.2%rdg+3dgt) |
5.000kW |
±(0.2%rdg+2dgt) |
50.00kW |
500.0kW |
5.000MW |
±(1.0%rdg+3dgt) |
50.00MW |
±(1.5%rdg+5dgt) |
Open Voltage: <1.3VDC, <3VDC for
50W&500W range |
Function-Capacity |
50.00nF |
±(0.8%rdg+3dgt) |
500.0nF |
5.000µF |
±(1.0%rdg+3dgt) |
50.00µF |
±(2.0%rdg+3dgt) |
500.0µF |
±(3.5%rdg+5dgt) |
9999µF |
±(5.0%rdg+5dgt) |
Function-DCA |
500.0µA |
±(0.2%rdg+4dgt) |
5000µA |
50.00mA |
500.0mA |
5.000A |
10.00A |
Function-ACA |
Bandwidth |
50~60Hz |
40~1kHz |
|
500.0µA |
±(0.6%rdg+3dgt) |
±(0.8%rdg+4dgt) |
5000µA |
50.00mA |
500.0mA |
±(1%rdg+3dgt) |
±(1.0%rdg+4dgt) |
5.000A |
±(0.6%rdg+3dgt) |
10.00A |
Frequency |
5.000Hz~125kHz |
±(0.01%rdg+2dgt) |
Temperture(PC520M/PC510) |
-50ºC~1000ºC |
±(0.3%rdg+3dgt) |
Continity buzzer |
Buzzer sounds at between 20W~120W
Open voltage: Approx. 3V |
Diode test |
Open voltage: Approx. 3.5V |
|
|
|
Function:
|
50000 &
500000 count |
5000 count |
PC5000 |
PC520M |
PC510 |
PC500 |
Best Accuracy in DCV |
0.03% |
0.08% |
0.08% |
0.08% |
Built-in Memory 43,000points |
|
 |
|
|
PC Link system (RS232
interface) |
 |
 |
 |
 |
True RMS |
 |
 |
 |
|
Capacitance |
 |
 |
 |
 |
Frequency |
 |
 |
 |
 |
Logic Frequency |
 |
|
|
|
Temperture K-type |
|
 |
 |
|
Temperture Platinic
thin film (Optional) |
 |
 |
 |
 |
0.01 mV resolution |
 |
 |
 |
 |
0.01 ohm resolution |
 |
 |
 |
 |
Auto leads calibration
for low ohm range |
|
 |
 |
 |
dBm measurement |
 |
|
|
|
Duty Cycle |
 |
|
|
|
%4-20mA |
 |
|
|
|
Diode test |
 |
 |
 |
 |
Continity buzzer |
 |
 |
 |
 |
MAX / MIN Recording |
 |
|
 |
|
MAX / MIN Capture
(Peak hold) |
 |
|
 |
|
Zoom Bargraph |
|
|
 |
|
Data Hold |
 |
 |
 |
 |
Relative measurement |
 |
|
 |
|
Auto Range |
 |
 |
 |
 |
Range hold |
 |
 |
 |
 |
Auto Power Off
(Enable or Disable) |
 |
 |
 |
 |
Alarm for mis-pulg
for Current range |
 |
|
|
|
Set off Beeper |
 |
 |
 |
 |
Tilt stand |
 |
 |
 |
 |
|
 |
 |
 |
Page